How Low Temperatures Impact Dye Penetrant Testing


Posted By: Steve Published: 10/16/2019 Times Read: 4173


The operating temperature range for penetrant inspection as specified in ASTM E1417 Standard Practice for Liquid Penetrant Testing is 40°F to 125°F (4°C to 52°C), but how is the penetrant inspection affected at temperatures below 40°F (4°C) and can the inspection process be adjusted to achieve acceptable results?

To answer these questions, we evaluated SKC-S cleaner/remover, SKL-SP2 solvent removable dye penetrant, and SKD-S2 non-aqueous developer at a range of temperatures in order to figure out what NDT inspectors can expect when using these, or similar quality dye penetrant products when inspecting at lower temperatures.


Cleaning at Lower Temperatures

At lower temperatures in the range of 32°F – 50°F (0°C – 10°C), the solvent cleaner will take longer to dry. We used 75°F (24°C) as our ambient, standard operating temperature, and observed how decreasing temperatures impacted how quickly the solvent cleaner dried. Below are our suggested drying time for solvent-based cleaner/removers at lower temperatures.

TEMPERATURECLEANER DRYING TIME
75°F / 24°CStandard
50°F / 10°C2 x Standard
40°F / 4°C3 x Standard
32°F / 0°C4 x Standard

It is critical to make sure the solvent has evaporated during the precleaning step either by wiping with a clean, lint free cloth or using air dryers to ensure a clean and dry part prior to penetrant application. Un-evaporated cleaner remaining in indications can impede penetrant entry into the surface breaking indications.


Developer at Lower Temperatures

Developer drying time is more of a challenge and our tests showed the developing action is impeded because of the slower solvent evaporation. When the developer dries, the indications become fuzzy or show excessive bleed out.


We were not able to get good results at 32°F (0°C) because the developer remained wet and did not dry within a reasonable amount of time. At 38° – 40°F (3° – 4°C), and with some air movement, developer film will dry at 5 times the standard time at 75°F (24°C).

TEMPERATUREDEVELOPER DRYING TIME
75°F / 24°CStandard
40°F / 4°C5 x Standard

A positive note is at low temperatures, we found good indications with extremely small and tight defects. The slow drying rate of the developer film allows greater bleed out of the penetrant from the defect. For large defects, longer development time caused excessive bleed out making indication interpretation more difficult.


Source:

Stockhausen, Cheri. "How Low Temperatures Impact Dye Penetrant Testing". Magnaflux Blog, 28 November 2017, https://www.magnaflux.com/Magnaflux/Blog/Low-Temperature-Dye-Penetrant-Testing

Products related to this post

Starting at $52.00

Starting at $45.00

Starting at $45.00

Related Posts

Selecting A Dye Penetrant Method

Selecting A Dye Penetrant Method

Three steps to narrow down a penetrant method through governing specifications, part composition, and test parts..

Author: Cheri Stockhausen, Product Applications Manager at Magnaflux Added: 05/08/2019 views: 1792

Read more