1. Check the condition of the yoke before each use

Check the power cord and switch to make sure they're in good condition. Check that the legs can bend to conform to the inspection surface. Check the feet to make sure they can make even contact with the inspection surface. The more contact area, the better.


2. Use a calibrated test weight to verify yoke strength

An AC yoke must lift 10 lb. / 4.5 kg, and a DC yoke must lift 50 lb. / 22.7 kg. Using just any piece of steel for the dead weight check can create a hazard for the operator; if the weight is not balanced it could slip off the yoke and drop. Calibrated test weights include alignment features to keep the weight balanced on the yoke, allowing you to perform the dead weight check safely.


3. Follow the rated duty cycle

The typical magnetic yoke has a 50% duty cycle with a maximum on time of 2 minutes. That means the yoke can be energized for up to 2 minutes continuously but would need to rest for the same amount of time afterward to prevent overheating. Exceeding the duty cycle can create a hazard for the operator and risk permanent damage to the yoke.


4. Never switch between AC and DC modes while the yoke is energized

Yokes are powerful electromagnets, and they carry large inductive loads. If an AC/DC yoke is switched from AC mode to DC mode (or from DC to AC) while the yoke is turned on, the feedback of the inductive load could permanently damage the internal components. Use caution when performing both AC and DC inspections to avoid accidental damage.


5. Clean the legs and feet after use

The legs and feet of yokes are steel laminations, and magnetic particles can become trapped in the joints. To keep the yoke in good working order for future use, clean out any trapped particles or dirt before storage.



For more information or to request a quote please follow this link or feel free to email or call us at [email protected] / 1-800-221-1116


Source:

Geis, David. "5-Point Guide to Yoke Best Practices". Magnaflux Blog, 29 October 2019. https://www.magnaflux.com/Magnaflux/Resources/Blog/Yoke-Best-Practices

Tags: non-destructive testing (ndt), magnaflux, magnetic particle inspection (mpi), yoke, best practices, contour probe, electromagnetic yoke, y-2, ac/dc, duty cycle,

Products related to this post

Starting at $1,250.00

Starting at $832.00

Related Posts

How to Use QQIs & Magnetic Flux Indicators

How to Use QQIs & Magnetic Flux Indicators

Magnetic Particle Inspection Flux Indicator Strips and Quantitative Quality Indicators (QQI) are defined and given a user manual approach to find artificial flaw standards..

Author: Steve Added: 08/22/2019 views: 4896

Read more